H2S Audit

Monitor, muster and breathing air where the well or the pad can hold H2S

Job
Detection
The well history was checked for H2S before the head was opened
Photo
Personal monitors were bump tested and the result was written down
Photo
Alarm set points match the site plan
Photo
Wind direction and the muster point are known to the crew
Photo
Response
People work in pairs where the plan requires it
Photo
Escape packs are at the head and people know how to don them
Photo
Supplied air is on the plan if the job can put someone in an H2S atmosphere
Photo
The rescue plan does not send an unprotected person into a known H2S release
Photo
Notes